Sample Snagging Survey Report, Cheshire
Customer Case Study & Sample Snagging Survey Report, Grayling Road Sandbach, Cheshire
Monday, 14 September 2020
“Very thorough and professional, would recommend and certainly work with again.”
The Report
LOCATION 1 5 GRAYLING ROAD SANDBACH
Assigned to Identification
The house has been built to a good standard throughout, there are a number of minor defects that need attention, which could have been avoided with a little more attention to detail. The extractor and boiler flue ducts need cavity trays installing (NHBC Standards 2020 Chapter 6.1.17). The majority of fire doors need adjusting throughout the house to comply with building regulations, the margins should be between 2 & 4mm.
LOCATION 2 FRONT ELEVATION
Assigned To Roofer
The lead flashing needs dressing flat to the wall to prevent water ingress.
LOCATION 3 FRONT ELEVATION
Assigned To Bricklayer
No weephole at the end of the cavity tray.
LOCATION 4 FRONT ELEVATION
Assigned To Roofer
The screw needs tightening in the bottom left hand ridge tile.
View full report
Snagging Report
Monday, 14 September 2020
59 Issues Identified